{"id":11147,"date":"2026-06-15T11:39:14","date_gmt":"2026-06-15T09:39:14","guid":{"rendered":"https:\/\/www.cami.it\/?p=11147"},"modified":"2026-06-15T14:07:57","modified_gmt":"2026-06-15T12:07:57","slug":"continuous-fine-oil-filtration-a-cami-solution-to-improve-the-reliability-and-service-life-of-hydraulic-systems","status":"publish","type":"post","link":"https:\/\/www.cami.it\/en\/continuous-fine-oil-filtration-a-cami-solution-to-improve-the-reliability-and-service-life-of-hydraulic-systems\/","title":{"rendered":"CONTINUOUS FINE OIL FILTRATION: A CAMI SOLUTION TO IMPROVE THE RELIABILITY AND SERVICE LIFE OF HYDRAULIC SYSTEMS"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In many high-production industrial plants, <strong>maintaining the correct hydraulic fluid cleanliness level is essential to ensure operational continuity<\/strong>, component reliability, and reduced maintenance costs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For a major application in the steel industry, CAMI was tasked with developing a <strong>dedicated microfiltration system for an existing hydraulic power unit, with the aim of improving fluid quality and protecting the most sensitive components of the circuit.<\/strong><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The Solution Developed by CAMI<\/strong><strong><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The solution consists of a <strong>standalone microfiltration unit installed on a dedicated steel skid, designed to operate continuously and independently from the main hydraulic power unit.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The unit is equipped with a <strong>SEIM three-screw pump<\/strong> <strong>driven by a high-efficiency 5.5 kW electric motor<\/strong>, a configuration particularly suited to ensuring constant flow, low pulsation levels, and long-term reliability.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">At the heart of the system is a <strong>HYDAC in-line filter with a filtration rating of 5 microns,<\/strong> specifically sized to effectively remove contaminating particles from the oil and help maintain optimal fluid conditions.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Integrated Monitoring and Diagnostics<\/strong><strong><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To ensure continuous monitoring of system performance, the unit incorporates <strong>dedicated devices for supervising operating conditions.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The differential clogging indicator provides real-time information on the condition of the filter element, while the electronic pressure switch with a 4\u201320 mA analog output enables integration with plant monitoring and maintenance systems.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The electrical control panel, designed and manufactured by CAMI<\/strong>, includes start-stop functions, emergency stop, power-on indication, and alarm management associated with operating conditions and filter status.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Benefits of Continuous Microfiltration<\/strong><strong><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The adoption of a dedicated microfiltration station makes it possible to maintain<strong> high hydraulic fluid cleanliness standards, reducing component wear and minimizing the risk of failures caused by particulate contamination.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Key benefits include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Increased hydraulic power unit reliability;<\/li>\n\n\n\n<li>Protection of pumps, valves, and precision components;<\/li>\n\n\n\n<li>Reduced downtime caused by contamination-related issues;<\/li>\n\n\n\n<li>Optimized maintenance activities;<\/li>\n\n\n\n<li>Extended service life of both the hydraulic oil and circuit components.<\/li>\n<\/ul>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Main Features of the Solution<\/strong><strong><\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>System designed for continuous operation.pre-set deviation.<\/li>\n\n\n\n<li>Painted self-supporting steel skid;<\/li>\n\n\n\n<li>5.5 kW IE3 electric motor;<\/li>\n\n\n\n<li>SEIM three-screw pump;<\/li>\n\n\n\n<li>HYDAC in-line filter with 10-micron filtration;<\/li>\n\n\n\n<li>Differential clogging indicator;<\/li>\n\n\n\n<li>Electronic pressure switch with 4\u201320 mA output;<\/li>\n\n\n\n<li>Integrated electrical control panel with alarm management;<\/li>\n<\/ul>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Description<\/strong><strong><\/strong><\/td><td><strong>Pump type<\/strong><strong><\/strong><\/td><td><strong>Power<\/strong><strong><\/strong><\/td><td><strong>Work pressure<\/strong><strong><\/strong><\/td><td><strong>Tank<\/strong><strong><\/strong><\/td><td><strong>Application field<\/strong><strong><\/strong><\/td><\/tr><tr><td><strong>CONTINUOUS MICROFILTRATION SYSTEM FOR INDUSTRIAL HYDRAULIC POWER UNITS<\/strong><\/td><td>THREE-SCREW PUMP<\/td><td>5.5 kW<\/td><td>max 10 bar<\/td><td>&#8212;&#8212;<\/td><td>STEEL INDUSTRY<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"576\" data-id=\"11149\" src=\"https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/1-1024x576.jpg\" alt=\"\" class=\"wp-image-11149\" srcset=\"https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/1-1024x576.jpg 1024w, https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/1-300x169.jpg 300w, https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/1-768x432.jpg 768w, https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/1-1536x864.jpg 1536w, https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/1.jpg 1600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"576\" data-id=\"11153\" src=\"https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/2-1024x576.jpg\" alt=\"\" class=\"wp-image-11153\" srcset=\"https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/2-1024x576.jpg 1024w, https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/2-300x169.jpg 300w, https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/2-768x432.jpg 768w, https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/2-1536x864.jpg 1536w, https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/2.jpg 1600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"819\" height=\"1024\" data-id=\"11155\" src=\"https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/1-quadro-819x1024.jpg\" alt=\"\" class=\"wp-image-11155\" srcset=\"https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/1-quadro-819x1024.jpg 819w, https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/1-quadro-240x300.jpg 240w, https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/1-quadro-768x960.jpg 768w, https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/1-quadro.jpg 1080w\" sizes=\"(max-width: 819px) 100vw, 819px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"819\" height=\"1024\" data-id=\"11151\" src=\"https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/2-intera-819x1024.jpg\" alt=\"\" class=\"wp-image-11151\" srcset=\"https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/2-intera-819x1024.jpg 819w, https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/2-intera-240x300.jpg 240w, https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/2-intera-768x960.jpg 768w, https:\/\/www.cami.it\/cspa\/wp-content\/uploads\/2026\/06\/2-intera.jpg 1080w\" sizes=\"(max-width: 819px) 100vw, 819px\" \/><\/figure>\n<\/figure>\n","protected":false},"excerpt":{"rendered":"<p>In many high-production industrial plants, maintaining the correct hydraulic fluid cleanliness level is essential to ensure operational continuity, component reliability, and reduced maintenance costs. For a major application in the steel industry, CAMI was tasked with developing a dedicated microfiltration system for an existing hydraulic power unit, with the aim of improving fluid quality and [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":11149,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[37,32],"tags":[],"class_list":["post-11147","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-case-history-cami-automation-en","category-case-history-cami-solution-en"],"_links":{"self":[{"href":"https:\/\/www.cami.it\/en\/wp-json\/wp\/v2\/posts\/11147","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.cami.it\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.cami.it\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.cami.it\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.cami.it\/en\/wp-json\/wp\/v2\/comments?post=11147"}],"version-history":[{"count":1,"href":"https:\/\/www.cami.it\/en\/wp-json\/wp\/v2\/posts\/11147\/revisions"}],"predecessor-version":[{"id":11161,"href":"https:\/\/www.cami.it\/en\/wp-json\/wp\/v2\/posts\/11147\/revisions\/11161"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.cami.it\/en\/wp-json\/wp\/v2\/media\/11149"}],"wp:attachment":[{"href":"https:\/\/www.cami.it\/en\/wp-json\/wp\/v2\/media?parent=11147"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.cami.it\/en\/wp-json\/wp\/v2\/categories?post=11147"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.cami.it\/en\/wp-json\/wp\/v2\/tags?post=11147"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}